How much clearance do you need for a gas range?

Gas ranges require a 6″ side wall clearance above the counter height for proper distance from combustible surfaces. Select models may only require a 3″ left side wall clearance based upon the burner configuration.

What is the minimum clearance needed to service a gas appliance?

The minimum clearance required directly above the range is 750 mm (approx 30″) to combustibles. This clearance can be reduced to 600 mm (approx 24”) when the finish is protected as per Article 9.10. 22.2. Vertical Clearances above Ranges of the Alberta Building Code.

How much space should be between stove and wall?

There should be two inches of space between the back wall and a drop-in or slide-in (gas or electric) style range. A freestanding range (gas or electric) requires no space between it and the back wall. There should be at least twelve inches between any style range and the closest sidewall.

What is the minimum clearance above a stove to combustible material?

(CMC 921.3. 2): Household cooking appliances shall have a vertical clearance above the cooking top of not less than 30 inches to combustible material or metal cabinets. A minimum clearance of 24 inches is permitted where one of the following is installed: 1.

How much clearance do you need above stove?

The International Residential Code, the building code on which most local building codes are based, requires a clearance of 30 inches between the top of a range and any combustible surface, but it specifies that over-the-range microwaves, which are designed to tolerate less clearance, should be mounted according to …

What is code for gas stove installation?

Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the gas range should be installed in accordance with the National Fuel Gas Code ANSI 223.1, latest edition and National Electrical Code ANSI/NFPA 70, latest edition.

Can I build a deck around a gas meter?

When a deck is built over a meter, it casts shade on the meter. For the same reason, a deck should not be built over a meter in a cold climate (though some utilities may allow you to build a small shed roof over the meter to protect it from freezing snowmelt and falling snow and ice).

What is the minimum distance between gas and other services?

n) The distance between vent outlets of a single meter gas compartment and electrical equipment shall be a minimum of 1000mm. For multiple meter compartments refer section 8. o) The co-location of gas and water meters inside a compartment or in proximity to each other is allowed.

How much space is needed around an oven?

Ovens must have a minimum of 15 inches of adjacent landing area on either side. However, because most ovens tend to be located under stoves as part of a single appliance, this landing area is usually already covered under the stove requirements.

Can a gas stove be flush against wall?

Can a gas stove be flush against the wall? Gas stoves have recessed areas in the back that should fit around the gas line, leaving only a 1-inch gap to avoid crimping the line. This lets the stove sit fairly close against the back wall.

How much clearance do you need above a stove?

At least one existing rule allows a minimum of 13 inches, but pro installers and others who know their way around kitchens argue that there should be 20 to 24 inches of clearance above the stove top.

How high should a range hood be above a gas stove?

between 24″ and 30″
In general, most installations require a distance from 20″ to 24″ between the bottom of the hood and the cooking surface. Over a gas range, this distance should be between 24″ and 30″, unless otherwise specified.

What is the building code in British Columbia?

The BC Building Code is a provincial regulation that governs new construction, and building alterations, repairs and demolitions. Building, renovation and demolition projects must comply with the code as well as applicable local government bylaws for zoning and permits.

What’s the minimum clearance for a gas range?

Many are made of expensive stainless steel and have multiple burners. All of these stoves have their own clearances to combustibles – clearly written in the manufacturers’ instructions. For example, for a 60” Wolf range the minimum vertical clearance between the gas range and combustible materials above the range is 44”.

What is the National Gas code for Canada?

(f) the National Standard of Canada CAN/CGA-B105-M93, Code for Digester Gas and Landfill Gas Installations, published January 1993, all as amended from time to time. 2 The national code is adopted in whole subject to the variations set out in the Schedule. 3 The national code, as amended, shall be known as the B.C. Natural Gas and Propane Code.

What is the code for propane storage and handling?

The object of the code is to prevent operational and safety hazards for the installation and storage of gas equipment. The applicable codes for homeowners are the CSA B149.1 Installation Code and the B149.2 Propane Storage and Handling Code. It is important to understand that the Code is a minimum requirement.